You are currently viewing only those items made visible to the public. Click here to sign in and view the full catalogue.
AVAILABILITY | Upon Request |
---|---|
TRAINING | Training is required to use this item and we can arrange this if needed. |
CUSTODIAN | Professor Jim Chandler |
---|---|
ADDITIONAL CONTACT | Nicholas Rodgers |
Enquire about this item | |
SITE | West Park |
The Trimble M3 DR 5" is a lightweight, compact total station that incorporates Trimble Accessâ„¢ field software that enables users to quickly collect, record and calculate survey data. Utilising long range Trimble DR (Direct Reflex) technology with precise Nikon optics and a Class 2 pointer laser, the EDM (Electronic Distance Measurement) device provides highly-accurate measurements that can easily be imported into CAD (Computer-Aided Design) software.
Typical Applications
Distance Measurement:
Good conditions (with reflector sheet, 5 cm x 5 cm) | 1.5 m to 300 m |
With single prism 6.25 cm | 1.5 m to 5,000 m |
Reflectorless mode (Good Conditions)
KGC (18%) | 250m |
KGC (90%) | 400m |
Accuracy:
(Standard Deviation based on ISO 17123-4)
Prism | ±(2+2 ppm × D) mm |
Reflectorless | ±(3+2 ppm x D) mm |
Measuring Interval:
Standard mode | 1.5 s |
Fast standard mode | 0.8 s |
Reflectorless Mode
Standard Mode | 1.8 s |
Fast Standard Mode | 1.0 s |
Least count
Standard Mode | 1 mm |
Fast Standard Mode | 10 mm |
Angle Measurement:
DIN 18723 accuracy (horizontal and vertical) | 1.5 mgon |
Reading system | Absolute encoder |
Circle diameter | 62 mm (2.4 in) |
Horizontal/Vertical angle | Diametrical |
Minimum increment (Degree, Gon, MIL6400) | Degree: 1/5/10" Gon: 0.2/1/2 mgon MIL6400: 0.005/0.02/0.05 mil |
Telescope:
Tube length | 125 mm |
Image | Erect |
Magnification | 30× (18x/36x with optional eyepieces) |
Effective diameter of objective | 45 mm |
EDM diameter | 50 mm |
Field of view | 1°20' |
Resolving power | 3" |
Minimum focusing distance | 1.5 m (4.9 ft) |
Laser Pointer | Coaxial Red Light |
Tilt Sensor:
Type | Dual-axis |
Method | Liquid-electric detection |
Compensation range | ±3.5' |
Communications:
Communication ports | 1 x serial (RS-232C), 2 x USB (host and client) |
Wireless communications | Integrated Bluetooth |
Power:
Source | Internal Li–ion battery (x2) |
Output voltage | 3.8 V DC |
Operating time | approx. 7.5 hours (continuous distance/angle measurement) approx. 16 hours (distance/angle measurement every 30 seconds) approx. 20 hours (continuous angle measurement) |
Charging time | 4 hours (Full Charge) |
General Specifications:
Sensitivity of Circular level vial | 10'/2 mm |
Tangent/Clamps | Endless |
Display face 1 | QVGA,16 bit color, TFT LCD, backlit (320x240 pixel) |
Display face 2 | Backlit, graphic LCD (128x64 pixel) |
Point memory | 128 MB RAM, 128 MB Flash memory |
Dimensions (W x D x H) | 149 mm x 145 mm x 306 mm |
Weight (approx.) | Main unit (without battery): 3.8 kg Battery: 0.1 kg Carrying case: 2.3 kg |
Environmental:
Operating temperature range | –20 °C to +50 °C |
Storage temperature range | –25 °C to +60 °C |
Atmospheric correction | |
Temperature range | –40 °C to +60 °C |
Barometric pressure | 400 mmHg to 999 mmHg/533 hPa to 1,332 hPa/15.8 inHg to 39.3 inHg |
Dust and water protection | IP66 |
Certification:
Class B Part 15 FCC certification, CE Mark approval. C-Tick. | |
Laser safety | IEC 60825-1 am2:2007 |
Reflectorless/Prism mode | Class 1 laser |
Laser Pointer | Class 2 laser |
Laser Plummet | Class 2 laser |
Bluetooth type approvals are country specific. |
Calibrated
Yes (September 2011).
Item ID #